What is the cause of noise in the pipe of dosing metering pump?
When the dosing metering pump works, sometimes the pipe will produce noise. Why? Isn't the compatibility of VAREM metering pump very strong? How to solve the noise phenomenon?
Firstly, the causes of pipe noise of dosing metering pump are analyzed, which mainly include the following four reasons:
1. The pipeline is too long;
2. The pipe diameter is too small;
3. No chambers or dampers are used.
4. The pulse baffle of VAREM dosing metering pump does not work or overflows;
In view of the above four reasons, Shanghai Longya pump valve Co., Ltd. gives the corresponding solutions in turn
1. Increase the pipe size and install pulse damper;
2. The pulse damper is installed in the pipeline;
3. Refill air or inert gas, check and replace diaphragm, refill;
4. Install pulse damper.
How to adjust the back pressure valve when the dosing metering pump is running?
When the dosing metering pump is running, it needs to use the safety valve, so how to adjust the safety valve? The safety valve is equivalent to the back pressure valve. The pressure of back pressure valve needs to be controlled reasonably. The safety valve is designed to prevent the dosing metering pump from overpressure operation, so how to adjust the back pressure valve in the operation process?
1. Do not exceed the working pressure of the VAREM metering pump.
2. When there is pressure at the suction end of the dosing metering pump, the pressure at the discharge end of the pump should be at least 1bar higher than that at the suction end.